Mineral oil in the power transformer has an important role in the cooling, insulation aging and chemical reactions such as oxidation. Oil temperature increases will cause quality loss. The oil should be regularly control in necessary time. Studies have been done on power transformers oils that are used in different age in Iranian power grid to identify the true relationship between age and other characteristics of power transformer oil. In this paper the first method to estimate the life of power transformer insulation (oil) is based on Arrhenius law. The Arrhenius law can provide loss of power transformer oil quality and estimates remaining life. The second method that is studies to estimate the life of power transformer is the paper insulation life prediction at temperature160 ° C.

References

Crine, J.P., 2005. "On the interpretation of some electrical aging and relaxation phenomena in solid

dielectrics", IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 12, No.6, pp.1089-

Emsley, A.M., Stevens, G.C., 1994. "Review of Chemical Indicators of Degradation of Cellulosic

Electrical Paper Insulation in Oil-Filled Transformers", IEE Proceedings-Science, Measure.

Technol. Vo1.141, No.5, pp.324-334.

Emsley, A.M., Heywood, R.J., Ali, M., Xiao, X., 2000. "Degradation of Cellulosic Insulation in Power

Transformers. 4. Effects of Ageing on the Tensile Strength of Paper", IEE Proceedings-Science,

Measure. Technol. Vo1.147, No.6, pp.285-290.

IEEE Standard, 1538-2000, 2000. "IEEE Guide for Determination of Maximum Winding Temperature

Rise in Liquid-Filled Transformers".

Lundgaard, L.E., Hansen, W., Linhjell, D., Painter, T.J, 2004. "Aging of Oil-Impregnated Paper in

Power Transformers", IEEE Transactions on Power Delivery, Vo1.19, No.1, pp.230-239.

Muthanna, K.T., Sarkar, A., Das, K., Waldner, K., 2006. "Transformer insulation life assessment" ,IEEE

Transactions on Power Delivery, Vol. 21, No. 1, pp. 150 – 156.

Pradhan, M.K., Ramu, T.S., 2005. "On the estimation of elapsed life of oil-immersed power

transformers", IEEE Transactions on Power Delivery, Vol. 20, No.3, pp.1962-1969.

Saha ,T.K., Purkait, P., 2004. "Investigation of polarization and depolarization current measurements

for the assessment of oil-paper insulation of aged transformers", IEEE Transactions on

Dielectrics and Electrical Insulation, Vol.11, No.1, pp.144-154.

Saha, T.K., Purkait, P., 2008. "Investigations of Temperature Effects on the Dielectric Response

Measurements of Transformer Oil-Paper Insulation System", IEEE Transactions on Power

Delivery, Vol. 23, No. 1, pp. 252-260.

Taghikhani, M.A., Rafiei, M., 2011. “Thermal Coefficient Measurements of Typical Distribution

Transformers Operating under Imbalance Conditions”, EPDC 2011, the16th Electric Power

Distribution Conference, Bandarabbas, Iran, April 19-20, pp 1-6.